20 mm
B
C
D
E
F
G
H
A
- 6.1 -
- 6.2 -
170 cm
INSTALLATION
ENGLISH
6 INSTALLATION
6.1 ASSEMBLY
DIAGRAM
Fig. 6.1 illustrates an example assembly diagram.
For proper installation, the smoke ducting between the
¿UHSODFHDQGWKHÀXHPXVWKDYHDOOMRLQWVVHDOHGXVLQJ
material suitable for high temperatures.
,IWKH¿UHSODFHLVLQVWDOOHGRQDÀXHXVHGSUHYLRXVO\
ZLWKRWKHU¿UHSODFHVLWLVQHFHVVDU\WRFOHDQWKRURXJKO\
WRDYRLGDEQRUPDOIXQFWLRQLQJDQGSUHYHQWD¿UHGXHWR
the combustible materials which deposit on the walls of
WKHÀXHSLSH
On all Ecomonoblocco units, on the outer sides of
WKH¿UHER[DQGWKHKRRGSDQHOVRIURFNZRROPXVWEH
installed with a thickness of 4 cm and a density of 40
NJP
3
on an aluminium foil base, to thermally insulate
WKH¿UHSODFH
Installation requirements include installation of a
heat recovery grille as close as possible to the ceiling
(around 20 cm).
Incorrect installation may compromise safety of the
unit.
7KHFODGGLQJPXVWEHPDGHRI¿UHSURRIPDWHULDO
,IWKHUHDUHÀDPPDEOHVWUXFWXUHVRUPDWHULDOVRQWKH
EDFNRIWKH¿UHER[WKHGLVWDQFHIURPWKHFRPEXVWLEOH
materials must be 20 cm.
All combustible materials must be placed at least 170
cm away from the area where heat radiates from the
glass door. (Fig. 6.2).
A) SEAL
B) EXTERNAL AIR INTAKE (UNDER FIRE BED)
C) HEAT RECOVERY GRILLE
D) COUNTER-HOOD AND FIREPROOF LOAD BEARING
STRUCTURE
E) CLADDING IN CERAMIC FIBRE OR ROCK WOOL WITH
EXTERNAL ALUMINIUM FOIL
F) INSPECTION PANEL
G) SHIELD THE WOOD PARTS WITH FIREPROOF MATERIAL
H) MINIMUM DISTANCE 5 mm BETWEEN CLADDING AND
FIREPLACE STOVE
cod. 004771651 MBL - 06/2015 - Palazzetti - PN - Italy
33