Procedure
1. Strip the wires so that the twisted ends will be the length
shown.
2. Referring to the diagram, twist the striped and solid lead
ends and attach the wires to the connector.
Note: Make sure the screws on the PCD connector are tightened
down firmly on the wiring.
CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
3. Remove power from the 5630.
WARNING
Always remove power before making or removing connections to
the unit. The motor terminals have high voltage present when the
5630 is On.
4. Plug the mating connector firmly into the 5630.
5. Connect the cable shield to 5630 ground, if applicable.
6. Switch On the 5630.
2.5.2 J2 115 Vac Power Connection
Introduction
The J2 115 Vac power cable connects voltage to the logic and
the motor power supplies.
Mating
Connector
The J2 115 Vac power input is for a PCD 3-pin screw mating
connector. The connector, supplied with the unit, is type
ELFH03110.
Cable
requirements
Use 16-to 14-gauge shielded wire for the cabling.
2 - 14
5630 Installation and Hardware Reference Manual
Rev E