Appendix D - Switch Summary
Introduction
This appendix summarizes the DIP switch settings for step
size, mid-range instability control, idle current reduction, and
current setting. These settings are covered in-depth in
Section 2.6.
Note: The arrow signifiy up or down as oriented from the
numbering on the switch. The character X signifies that the
switch setting does not need to be specified (can be in either
position).
Step Set Up
For step size ... Move switch settings to ...
1
2
3
4
5
6
7
8
full
↓
↓
↓
X
X
X
X
X
1/2
↑
↓
↑
X
X
X
X
X
1/5
↑
↓
↓
X
X
X
X
X
1/25
↓
↑
↓
X
X
X
X
X
1/125
↓
↓
↑
X
X
X
X
X
Mid-range
Instability Control
Set Up
Mid-range
Instability
Control Set up
Move switch settings to ...
1
2
3
4
5
6
7
8
Enable
X
X
X
↑
X
X
X
X
Disable
X
X
X
↓
X
X
X
X
Rev E
5630 Installation and Hardware Reference Manual