Cabling
diagram
The colors referenced in the diagram follow the Pacific
Scientific stepper motor color code.
Procedure
1. Strip the wires to 0.27 inch (7 mm).
2. Referring to the diagram, attach the wires to the
connector. Connect the white-striped leads with wire nuts
as shown.
Note: Make sure the screws on the PCD connector are tightened
down firmly on the wiring.
CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
3. Remove power from the 5630.
2 - 12
5630 Installation and Hardware Reference Manual
Rev E
1
2
3
4
5
To
Drive
To
Motor
A (Black)
A (Orange)
B (Red)
B (Yellow)
Motor Case
Gnd (Green)