Procedure
1. Strip the wires to 0.27 inch (7 mm).
2. Attach the wires to the connector as indicated in the
diagram.
Note: Make sure the screws on the PCD connector are tightened
down firmly to the wiring.
CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
3. Remove power from the 5630.
WARNING
Always remove power before making or removing connections to
the unit. The motor terminals have high voltage present when the
5630 is On.
4. Plug the mating connector firmly into the 5630.
5. Connect the cable shield to 5630 ground, if applicable.
6. Plug the other mating connector into the motor.
7. Switch On the 5630.
2.5.1.2 8-Lead Motor, Series Connected
Introduction
For an 8-lead motor to be wired in series, build and install the
cable as follows:
Cable
requirements
Use 16- to 14- gauge stranded wire for the cabling. Obtain
cable with each winding pair (see diagram) twisted at about 3
to 4 turns per inch (1 to 1.5 turns per centimeter). Make sure
the cable contains a lead for grounding. As an option, the
cable may be shielded to reduce radiated noise.
Rev E
5630 Installation and Hardware Reference Manual
2 - 11