![Pacific Power Source ASX series Скачать руководство пользователя страница 90](http://html.mh-extra.com/html/pacific-power-source/asx-series/asx-series_operation-manual_746368090.webp)
82
SECTION 6
CALIBRATION
6 CALIBRATION
This section describes the calibration of the ASX-Series AC Power Source.
6.1 CALIBRATION
INTERVAL
The ASX-Series Power Source requires calibration once every six months or after service has
been performed to the system.
6.2
TEST EQUIPMENT REQUIREMENTS
The test equipment listed below is required for calibration of the ASX-Series Power Source.
1.
Digital Voltmeter:
4½ Digit True-RMS responding 5000 Hz bandwidth, min.
2.
Frequency counter:
5 digit counter, min.
3.
Digital Ammeter: 3½ Digit True-RMS responding 5000 Hz bandwidth, min.
(Alternate
Approach:
Current
transformer used in conjunction with the DVM.)
4.
Oscilloscope:
(Optional)
5.
Load (Resistive):
Varies by model number
Current requirement @
Voltage Model
Name
10A/1
φ
@ 132 VAC
l-n
Model
115-ASX
10A/1
φ
5A/
φ
- 2
φ
@ 150 VAC
l-n
Model 120-ASX
26A/1
φ
13A/
φ
- 2
φ
@ 135 VAC
l-n
Model 140-ASX
40A/1
φ
13.3A/
φ
- 2
φ
@ 132 VAC
l-n
Model 160-ASX
10A/1
φ
3.3A/
φ
- 3
φ
@ 132 VAC
l-n
Model 315-ASX
10A/1
φ
3.3A/
φ
- 3
φ
@ 150 VAC
l-n
Model 320-ASX
30A/1
φ
10A/
φ
- 3
φ
@ 135 VAC
l-n
Model
345-ASX
40A/1
φ
13.3A/
φ
- 3
φ
@ 132 VAC
l-n
Model
360-ASX
80A/1
φ
26A/
φ
3
φ
@ 135 VAC
l-n
Model
3120-ASX
Содержание ASX series
Страница 2: ......
Страница 8: ......
Страница 21: ...SECTION 2 SPECIFICATIONS 13 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 A MODEL 115 ASX OUTPUT DERATING CURVES ...
Страница 22: ...SECTION 2 SPECIFICATIONS 14 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 B MODEL 120 ASX OUTPUT DERATING CURVES ...
Страница 23: ...SECTION 2 SPECIFICATIONS 15 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 C MODEL 140 ASX OUTPUT DERATING CURVES ...
Страница 24: ...SECTION 2 SPECIFICATIONS 16 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 D MODEL 160 ASX OUTPUT DERATING CURVES ...
Страница 25: ...SECTION 2 SPECIFICATIONS 17 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 E MODEL 315 ASX OUTPUT DERATING CURVES ...
Страница 26: ...SECTION 2 SPECIFICATIONS 18 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 F MODEL 320 ASX OUTPUT DERATING CURVES ...
Страница 27: ...SECTION 2 SPECIFICATIONS 19 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 G MODEL 345 ASX OUTPUT DERATING CURVES ...
Страница 28: ...SECTION 2 SPECIFICATIONS 20 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 H MODEL 360 ASX OUTPUT DERATING CURVES ...
Страница 29: ...SECTION 2 SPECIFICATIONS 21 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 I MODEL 3120 ASX OUTPUT DERATING CURVES ...
Страница 69: ...SECTION 3 INSTALLATION 61 3 4 2 SPLIT PHASE OUTPUT cont FIGURE 3 4 2 1 SPLIT PHASE OUTPUT CONNECTION ...
Страница 70: ...SECTION 3 INSTALLATION 62 3 4 2 SPLIT PHASE OUTPUT cont FIGURE 3 4 2 2 SPLIT PHASE OUTPUT CONNECTION ...
Страница 72: ...SECTION 3 INSTALLATION 64 3 4 3 THREE PHASE OUTPUT cont FIGURE 3 4 3 1 THREE PHASE OUTPUT CONNECTION ...
Страница 73: ...SECTION 3 INSTALLATION 65 3 4 3 THREE PHASE OUTPUT cont FIGURE 3 4 3 2 THREE PHASE OUTPUT CONNECTION ...
Страница 76: ...SECTION 3 INSTALLATION 68 3 5 CONNECTION OF SYSTEM CONTROL UNIT SCU cont FIGURE 3 5 1 SCU CONNECTION ...