System Set-Up
Set up the ST 145 system using the following steps and associated drawings.
1. Store the shipping container in a convenient location. Reuse of these
containers will prevent damage if you store or ship your system.
2. Place the Power Switch in the “OFF” or “0” position.
Tip & Tool Stand
The Tip & Tool Stand can be mounted to the power source. If the system will be placed on the
workbench, this is recommended. If the ST 145 is to be mounted under the workbench or shelf, the
Tip & Tool Stand should not be mounted to the power source.
1. To attach the stand to the power source:
a)
Insert the 2 Mounting Screws (head first) into the
power source mounting slots (plastic case shown).
Slide the screws toward rear of the power source.
b) Place the Tip & Tool Stand beside the power source.
Insert ends of the 2 Mounting Screws into the 2 Tip &
Tool Stand mounting holes as shown.
c) Install a Thumb Nut onto the end of each Mounting
Screw and tighten Thumb Nuts.
2. Place the handpiece into its Tip & Tool Stand.
Handpiece Connection
Connect the handpiece connector plug into the Power Receptacle in
the following manner.
1. Align guide on connector with slot on power receptacle.
2. Insert connector into power receptacle.
3. Turn the connector housing clockwise to lock in place.
CAUTION:
Ensure that only one air hose is connected to the
VACUUM
or controllable
PRESSURE
port at one time. Attachment to both ports
simultaneously will cause deterioration in performance.
TEKLINK
The TEKLINK receptacle located on the back panel of the power supply allows
you to interface the
VACUUM
and
PRESSURE
features of your ST 125/145
with the SODRTEK ST 25/45 system. This feature gives you the freedom to
operate air-controlled handpieces (SX-70/80, TP-65, or TJ-70/80) from an ST
25/45 system through the
VACUUM
and
PRESSURE
ports of your ST
125/145. To link your ST 125/145 system to the ST 25/45 system, perform the
following procedure.
TEKLINK Receptacle
©2004 PACE Inc., Annapolis Junction, Maryland
Page 6 of 22