5. The displayed temperature will decrease and stabilize at 177°C (350°F) when
the system is in Temperature Setback.
6. "OFF" when the Set Tip Temperature has been set to Off (below minimum
set tip temperature). Refer to the "Set-Up Mode" portion of this manual.
7. "OFF" plus the LED Display will be flashing when the unit has entered Auto
Off. Refer to the "Set-Up Mode" portion of this manual.
8. Error messages ("OSE", "SSE" or "OCE") if a system fault is detected. Refer
to the "Corrective Maintenance" portion of this manual.
LED Display, Temperature Adjust Mode
The LED Display will show the following when adjusting the desired Set Tip Temperature.
1. The Set Tip Temperature.
2. "HiL" (High Temperature Limit) when adjusting the set tip temperature and
the maximum allowable temperature is exceeded. Refer to the "Set-Up
Mode" portion of this manual.
3. "OFF" (Low Temperature Limit) when adjusting the set tip temperature and
the minimum allowable temperature is exceeded. Refer to the "Set-Up Mode"
portion of this manual.
4. "EP0" will be displayed if a Set Tip Temperature adjustment is attempted and
a Password has been stored in system memory. As the 5 key Password is
entered, the zero will increase by one as each key entry is made. Upon entry
of the fifth password key, the display will change to the Set Tip Temperature
if the entered Password matches the stored Password.
5. "no" will be displayed if the entered password does not match the stored
Password.
Vacuum Pump Operation
The PACE ST 145 contains two different vacuum pumps.
1. HiFlo
Pump
a) To activate, depress the handpiece activation button.
b) Optional Foot Pedal can be used to actuate the HiFlo pump via the rear TEKLINK
socket.
2. LoFlo
Pump
a) This pump is activated by the front Illuminated LoFlo Pump Switch.
b) For use with the TJ-80 and PV-65 Pik Vac Wand.
Handpiece Vacuum/Pressure
To set up your Sodr-X-Tractor air hose connection, perform the following steps: