Temperature Limit (up to 482°C, 900°F). Press and release the Program Key to proceed
to the next step.
c) Press and release the Scroll Down
Key to decrease the stored High Temperature
Limit. Press and release the Program (
) Key to proceed to the next step.
10. The LED Display now shows the stored default Low ("Lo") Temperature
Limit with the display alternating to show "Lo" and the stored limit.
Choose one of the following:
a) Press and release the Program (
) Key to keep the stored Low
Temperature Limit (204°C, 400°F min.).
b) Press and release the Scroll Up
Key to increase the stored Low Temperature Limit.
Press and release the Program (
) Key to proceed to the next step.
c) Press and release the Scroll Down
Key to decrease the stored Low Temperature
Limit. Press and release the Program (
) Key to proceed to the next step.
Offset Constant
11. The LED Display now shows the stored Offset Constant with the display alternating to show
"OF" and the stored Offset Constant. Choose one of the following:
a) Press and release the Program (
) Key to keep the currently
stored
Offset
Constant.
b) Press and release the Scroll Up
Key to increase the stored Offset Constant. An
Offset Constant of 0-133°C (0-240°F) can be stored. Press and release the Program (
) Key to proceed to the next step.
c) Press and release the Scroll Down
Key to decrease the stored Offset Constant.
Press and release the Program (
) Key to proceed to the next step.
NOTE:
If the attached handpiece is disconnected when the system is powered up, any
stored Offset Constant is reset to zero. The Offset Constant must be entered again
in the Set-Up Mode.
Temperature Setback
12. The LED Display now shows the stored Temperature Setback time as
"S-X" (x=0 thru9). Time is shown as tens of minutes (e.g., "S-
3" equals 30 minutes). A display of "S- 0" indicates that Setback is
disabled. Choose one of the following:
a) Press and release the Program (
) Key to keep the currently stored Temperature
Setback time.
b) Press and release the Scroll Up
Key to enable and/or increase the stored
Temperature Setback time. Press and release the Program (
) Key to proceed to the
next step.
c)
Press and release the Scroll Down
Key to decrease or disable the stored
Temperature Setback time. Press and release the Program (
) Key to proceed to the
next step.
©2004 PACE Inc., Annapolis Junction, Maryland