7. Enable or disable the Average Temperature feature. The following instructions should be
performed to familiarize the operator with the system.
Entering Set-Up Mode
1. Place Power Switch in the “OFF” (“0”) position.
2. Press and hold the Program (
) Key.
3. Place Power Switch in the "ON" (“I”) position. Release the Program (
) Key.
Password
4. The LED Display will display the version of the microprocessor and
change to read “P--” or "EP0".
5. If the display reads "EP0", a Password has been stored in system
memory. Enter the 5 key sequence Password. If the Password entered
is incorrect, "no" appears on the display and the system then returns to
normal operation. If this occurs, repeat steps 1 through 5 and enter
the correct Password.
6. The LED Display reads "P- -". Choose one of the following options:
a) Press the Program (
) Key to keep the currently stored Password (including no
Password).
b) Press and release the Scroll Up
Key to enter a new Password.
c) Press and release the Scroll Down
Key if you wish to remove a stored password or
do not wish to store a Password.
7. If the LED Display now reads "EP0", select and enter a 5 key password sequence. Make a
note of the entered Password. As the Password is entered, the last digit of the display will
count up with each key entry. After the fifth key entry, proceed to step 8.
Temperature Scale
8. The LED Display now shows the stored default Temperature Scale (°C
or °F temperature shown on LED Display). Choose one of the following:
a) Press the Program (
) Key to keep the stored default
Temperature
Scale.
b) Press and release the Scroll Up
Key to change the default Temperature Scale. Press
and release the Program (
) Key.
Temperature Limits
9. The LED Display now shows the stored default High ("Hi") Temperature
Limit with the display alternating to show "Hi" and the stored limit.
Choose one of the following:
a) Press and release the Program (
) Key to keep the stored High
Temperature Limit.
b) Press and release the Scroll Up (s) Key to increase the stored High
©2004 PACE Inc., Annapolis Junction, Maryland
Page 8 of 22
All Rights Reserved