Factory Settings
The ST 145 system comes equipped with a number of features which may be
adjusted, enabled or disabled as desired by the user. Listed below are the features
and factory settings of each. To change and/or learn about any of these features,
refer to the applicable part of the “Set-Up Mode” portion of this manual.
FEATURE
FACTORY SETTING
Password None
Entered
Default Temperature Scale (°C/°F)
°F for 115V Systems
°C for 230V Systems
"Hi L" (upper) Temperature Limit
482°C (900°F)
"LO" (lower) Temperature Limit
204°C (400°F)
Set Temperature
"OFF"
Tip Offset Constant
"0"
Temperature Setback
Enabled
Setback Time
30 Minutes
Auto Off
Enabled
Time To Auto Off
30 Minutes
Definitions
Please read and become familiar with the definitions of each of the following terms which are used
repeatedly in the following operational procedures.
AUTO OFF
- Safety feature which turns power off (10-90 minutes, settable in 10 minute increments)
after the system has entered Temperature Setback.
NORMAL OPERATION
- Normal operating mode of the system in which the Operating Tip
Temperature is displayed.
OPERATING TIP TEMPERATURE
- The true tip temperature at which the handpiece tip operates at
any given time.
SET TIP TEMPERATURE
- The operator selected idle tip temperature entered into the system
memory.
SET-UP MODE
- Mode of operation in which the operator can quickly and easily adjust the system
parameters (e.g., temperature limits, password, setback time).
TEMPERATURE ADJUST MODE
- Mode of operation in which the operator can quickly and easily
adjust the Set Tip Temperature.
TEMPERATURE DISPLAY IMPEDANCE (TDI) MODE -
Stabilizes the tip temperature shown on the
LED Display by ignoring minor temperature fluctuations. Displayed changes in temperature are
delayed (impeded) for two seconds when a load is applied to the tip. Two seconds after the load is
removed, the displayed temperature will begin rising to set temperature. Particularly useful in a