MAINTENANCE
5. Wipe all surfaces clean using a damp, non-abrasive cloth.
6. Wipe dry all surfaces using a non-abrasive, dry cloth.
7. Perform the “Daily Cleaning” procedure in this section.
Cleaning the Slider assembly
Monthly Cleaning
1. Turn off the Standby switch and allow unit to cool. Cooling
fans will operate until the oven chamber temperature drops
below 140°F (60°C).
2. after the cooling fans shut off, disconnect the unit from the
power supply:
• For model m1313, unplug the power cord.
• For model m1718, move the main Disconnect switch to
the OFF (O) position.
3. Remove and clean the two air filters on the back of the
oven. To clean each filter:
a. Slide the filter straight out the side of the filter bracket.
b. Spray the filter with water and/or soak in soap and
water.
c. Rinse clean and allow the filter to air dry.
d. When the filter is dry, reinstall the filter into the filter
bracket.
Spray and clean right side
of center divider.
Spray and clean left side
of center divider.
Spray and clean
each end cap.
IMPORTANT NOTE
:
Use of cleaning chemicals not approved by Ovention when
cleaning the oven chamber will void the warranty.
Cleaning the air Filters
4. Remove and clean the upper and lower jet plates inside the
oven chamber. To clean the jet plates:
a. Unlatch and open the oven door so that the inside of the
oven chamber is exposed.
b. Remove the upper and lower jet plates. Remove the
plates by pulling the handles straight out of the oven.
c. Spray Chemco Dirt Buster III Oven Cleaner onto both
sides of each jet plate. allow the cleaner to sit for 3
–
5
minutes.
d. Using a non–abrasive nylon scouring pad, apply
pressure to wipe away grease residue.
e. Wipe the jet plates clean using a damp, non-abrasive
cloth and allow to air dry. Do not reinstall at this time.
Cleaning the Jet Plates
5. Clean the visible areas of the oven chamber using the
same procedure as the jet plates (steps “c” through “e”
above).
6. Reinstall the upper and lower jet plates into the oven
chamber.
7. Close the oven door and secure both door latches.
8. Perform the “Weekly Cleaning” procedure in this section.
Upper
Jet Plate
Oven
Door
Lower
Jet Plate
Door
Latch
Handle
Cord removed for clarity.
Air Filter
Temperature
High-Limit
Reset Button
Air Filter
Filter Bracket
Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454