Troubleshooting
49
Each of the LEDs shown above indicates the connectivity status of the PCIe card inserted into the respective PCIe slot. Once connectivity has
been established between the host computer and one (or more) PCIe cards, the respective LED(s) will light up. The Uplink Port LED will light up
as soon as the chassis had linked with the host system regardless of how many PCIe cards are installed in the chassis, or if none at all. Therefore
in normal working conditions it should always be lit.
The activity LEDs will blink occasionally whenever the host is communicating with the card is a respective slot.
6.2 SNMP Power-On Source Jumper
The SNMP module inside the EB7-X8G2-RAS chassis features a power-on source jumper to select between local power-on (via the master
on/off switch) and remote turn-on (via the SNMP software/front end).
In order to gain access to this module (and respective jumper), the top cover of the chassis needs to be removed.
Dismount the chassis from the rack (if applicable) and carefully remove the screws holding the chassis cover in place.
The SNMP module will be located on the right side of the unit oriented with the fans facing us.