Ones Stop Systems
EB7-X8G2-RAS | 4
Install PCIe Cards
35
Under the MIB Tree, the OSS Chassis will have status information that can be read by expanding the respective folders. This information is also
available in the Web interface mentioned previously. In addition, if we expand the
sendAction
folder (as shown above) we gain
access to “writable” functions that essentially allow us to remote-control the chassis.
Remote Chassis Reset (turnPowerOffOn)
This function allows us to remotely turn the chassis off and on.
Right-click on it, and an options menu will appear. Select the “
Set
“command:
IMPORTANT
In order to successfully apply this function you must first set the
SNMP Power-on Jumper
in
the position between PS_ON and ON_BY_MCU. This is
not
the default position of that jumper.
Additionally, the chassis’ master on/off switch as well as each of the redundant power
supplies’ switches must be turned ON.