SECTION 3 - CHASSIS & TURNTABLE
3-32
– JLG Lift –
3121623
Troubleshooting
These Instructions are valid for machines with the
engine the key switch.
Figure 3-58.
Identify the plug X-51 that feed the fuel pump shutoff to
the machine system.
Figure 3-59.
Disconnect the plug X-51.
Figure 3-60.
On grey connector make a wire to connect the pin 1 to the
positive terminal of the battery and another at pin 2 to
ground or battery.
Figure 3-61.
Attempt to start the engine by key switch
Figure 3-62.
To shutdown the engine disconnect the wires.