Operator Manual
Cha
pt
er
:
Di
ag
no
st
ics
27
Warning 4: USB Pendrive not found
Symptom:
The pendrive has not been detected in the relevant housing.
Solution:
Check the correct insertion of the pendrive in the housing. If it is not detected or the Pendrive is not inserted, the data of
the current work session cannot be saved. The message disappears automatically after 10 seconds
Warning 5: Filters Cleaning
Symptom:
The filters positioned on the vacuum nozzles have reached 300 operating hours.
Solution:
Touch the screen to remove the indication and replace the filters present in the equipment.
Warning 6: LASER temperature too cold
Symptom:
The temperature of the internal electronics is too low
Solution:
Install the equipment in a warmer place, avoid high temperature changes. Wait for the equipment to reset automatically,
do not switch off, leave it on to quicken up the process. If it does not take place automatically, contact the technical after-
sales assistance
Warning 10: Safety Panel Open
Symptom:
The panel has been removed or not inserted correctly
Solution:
Re-position the panel in its seat.