Errors and warnings
If one of the following messages appears on the display, operate as described in the "Solution" section of the message.
Error 1: H2O flux failure
Problem:
The flow sensor does not detect any liquid in the cooling circuit
Solution:
Check the correct level of the liquid
Check the water filter is not clogged
Contact the technical after-sales assistance
Error 2: Charge fail Chap.
Problem:
The internal capacitors are not charged correctly
Solution:
Check suitability of the electric plant
Check there are no problems with the electricity supply
Check the correct operating voltage
Contact the technical after-sales assistance
Error 3: Simmer failure
Problem:
The lamp is not working or is not in pre-switch on (Simmer)
Solution:
Check the number of shots performed
Contact the technical after-sales assistance
Error 4: Shutter failure
Problem:
The safety shutter in the resonator does not close or does not work correctly
Solution:
Contact the technical after-sales assistance
Error 5: RS-232 fail
Problem:
Communication between the internal circuit boards does not work
Solution:
Contact the technical after-sales assistance
Warning signals
The "Warning" signals appear for conditions outside the job and can be solved without having to switch the equipment off
Warning 1: Remote interlock
Symptom:
The remote interlock switch contact is open
Solution:
Close the contact to restore the work session
Warning 2: H2O too hot
Symptom:
The temperature of the coolant is too high.
Solution:
Wait for the equipment to reset automatically, do not switch off, leave it on to quicken up the cooling process.
If it does not take place automatically, contact the technical after-sales assistance
Warning 3: CCPS too hot
Symptom:
The temperature of the internal electronics is too high
Solution:
Wait for the equipment to reset automatically, do not switch off, leave it on to quicken up the cooling process.
If it does not take place automatically, contact the technical after-sales assistance
WARNING!
The equipment must NOT be installed in an environment that is too hot and away from heat sources; the higher the ambient
temperature, the lower the efficiency of the cooling circuit/heat exchanger will be.