Monitoring and Analysis Tools
Calibrating and Activating Noise Floor Correction
OceanTRx
TM
4-500 Installation and Operations Manual
9-15
3. Open the
Noise-Floor
menu and select
Start Calibration
.
The
Start Noise-Floor
Calibration
dialog box appears.
Figure
9-18: Start Noise-Floor Calibration Dialog Box
4. Check the relevant calibration lines in accordance with the LNB bands (single, dual or
quad). The lines are ordered by LNB bands according to the LNB voltage/tones and by
NBR IfBw (50KHz, 150KHz and 300KHz).
NOTE:
Calibrating an excess number of lines (for example, all lines for a single-band LNB) will
result in the measurement time increasing, but does not affect the system adversely. Any
extraneous information is ignored.
5. Click
Start (Enter)
. The calibration process runs in a fully automatic manner,
scanning the calibration lines one by one. Each line takes approximately 100 seconds.
6. After the process is complete, the final results are displayed in the
Write Noise-Floor
Calibration
dialog box. Refer to examples in section
7. Click
Write (Enter)
. The
Write Noise-Floor Calibration
dialog box closes.
Figure
9-19: Write Noise-Floor Calibration Dialog Box