Monitoring and Analysis Tools
Spectrum Analyzer Tool
OceanTRx
TM
4-500 Installation and Operations Manual
9-5
9.1.2
Acquisition Criteria
These are the criteria according to which the data will be acquired. These include (among
other parameters), the measurement steps and the acquisition rate per step
(measurement point).
Duration of a measurement point = 2.5 milliseconds (ms).
Duration of a complete band = (Number of averaging points)*(Number of steps)*(0.0025).
Example:
( ( ) ( )) ( )
( )
( ) ( )
Maximum number of measured points is 25,000.If the span-to-step ratio exceeds this number, an
error message would be sent to the user.
NOTE:
The bandwidth filters (which effectively function as the
Spectrum Analyzer Screen
resolution
bandwidth) can be set to 50 KHz, 150 KHz and 300 KHz bands, depending on the carrier’s bandwidth.
To define the acquisition criteria
1. In the
Spectrum Analyzer
screen, open the
Configuration & View
menu and select
General Config
. The
Configuration
dialog box appears.
Figure
9-2: Spectrum Analyzer Configuration Dialog Box
2. Set the following parameters:
Start
Frequency
and
Stop Frequency
.
Frequency Step
– Frequency measurements steps.
Range: 0.005 MHz to 1.0 MHz(default step).