![Orbit OCEANTRX4-500 Скачать руководство пользователя страница 175](http://html1.mh-extra.com/html/orbit/oceantrx4-500/oceantrx4-500_installation-and-operation-manual_1648014175.webp)
Appendix C. Status Messages
OceanTRx
TM
4-500 Installation and Operations Manual
3
Controller Screen Label
Description
WRN 081: Tilt Driver Temperature High
The tilt axis servo-driver temperature is above the alarm
temperature setting.
WRN 082: Tilt Driver Memory Error
The tilt axis servo driver failed one of its memory test
routines.
WRN 083: Tilt Communication Error
There was a checksum error or timeout on commands
received for the tilt axis.
WRN 084: Tilt 96V out of Range
Input 96V power is too high or low on the tilt axis.
WRN 087: System ID Changed
The system ID changed.
WRN 101: Satellite Database is Truncated
The satellite database file is truncated.
WRN 102: Receiver Cal Table not Found
The ACU could not find the internal NBR calibration file in
its flash memory (C:\) on power-up.
WRN 121: Azimuth was not Initialized
The azimuth axis has not yet performed its initialization
procedure.
WRN 124: Azimuth CW Software Limit
The azimuth axis has reached its CW software limit.
WRN 125: Azimuth CCW Software Limit
The azimuth axis has reached its CCW software limit.
WRN 126: Azimuth Driver Temperature High
The azimuth axis servo-driver temperature is above the
alarm temperature setting.
WRN 127: Azimuth Driver Memory Error
The azimuth axis servo driver failed one of its memory test
routines.
WRN 128: Azimuth Communication Error
There was a checksum error or timeout on commands
received for the azimuth axis.
WRN 129: Azimuth 96V out of Range
Input 96V power is too high or low on the azimuth axis.
WRN 134: Elevation was not Initialized
The elevation axis has not yet performed its initialization
procedure.
WRN 137: Elevation CW Software Limit
The elevation axis has reached its CW software limit.
WRN 138: Elevation CCW Software Limit
The elevation axis has reached its CCW software limit.
WRN 139: Elevation Driver Temperature High
The elevation axis servo-driver temperature is above the
alarm temperature setting.
WRN 140: Elevation Driver Memory Error
The elevation axis servo-driver has failed one of its
memory test routines.
WRN 141: Elevation Communication Error
There has been a checksum error or timeout on
commands received for the elevation axis.
WRN 142: Elevation 96V out of range
Input 96V power is too high or low on the elevation axis.
WRN 147: PolSkew was not Initialized
The polarization skew axis has not yet performed its
initialization procedure.
WRN 150: PolSkew CW Software Limit
The polarization skew axis has reached its CW software
limit.
WRN 151: PolSkew CCW Software Limit
The polarization skew axis has reached its CCW software
limit.
WRN 152: PolSkew Driver Temperature High
The polarization skew axis servo-driver temperature is
above the alarm temperature setting.
WRN 153: PolSkew Driver Memory Error
The polarization skew axis servo driver failed one of its
memory test routines.