Table 9: Input Source Switching behaviour
Output > Display Mode > I/O Lock
I/O Lock = On
I/O Lock = Genlock
I/O Lock = Off
(Free Run mode)
Output > Display
Mode > Frame Rate =
Auto
Switching is not
clean
NOT A VALID CONDITION
Depends on Inputs
Output > Display
Mode > Frame Rate =
Fixed (any)
Switching is not
clean
Always Clean
Always Clean
If the output Frame rate is set to Auto, all types of genlock signals (e.g. NTSC & PAL, Tri-level sync)
signals are accepted. On the other hand, if a specific frame is selected, for example 59.94Hz, only a
Genlock reference signal of 59.94Hz is accepted and the unit will not lock to a 50Hz reference signal.
If the output Frame rate is set to Auto and I/O lock is off, input switching may-not be clean. Clean
switching will depend how close the frame rates of the current and next input channel are.
Settings:
Off, On, Genlock (for models supporting genlock)
Default:
Off (Free Run)
6.2.1.4
FR Enable
From this menu, the user can choose the output frame rates that the unit outputs. This menu can be
used to prevent the unit from outputting frame rates that cannot be accepted by the display.
Settings:
60 Yes/No, 50 Hz Yes/No, 48 Yes/No, 30/29.97Hz Yes/No, 25 Yes/No, 24/23.98 Yes/No
Default:
60Hz Yes, 50Hz Yes, 48Hz No, 30/29.97Hz Yes, 25Yes, 24/23.98Hz Yes