LTDVE8CH-20 – INSTRUCTION MANUAL
58
14.2.48. Registers CALIB_CUR_MUL[0:7]
These registers contain calibration constants for measurement of light output currents.
CALIB_CUR_MUL0
: calibration constant for measurement of light output LD1 current
CALIB_CUR_MUL1
: calibration constant for measurement of light output LD2 current
CALIB_CUR_MUL2
: calibration constant for measurement of light output LD3 current
CALIB_CUR_MUL3
: calibration constant for measurement of light output LD4 current
CALIB_CUR_MUL4
: calibration constant for measurement of light output LD5 current
CALIB_CUR_MUL5
: calibration constant for measurement of light output LD6 current
CALIB_CUR_MUL6
: calibration constant for measurement of light output LD7 current
CALIB_CUR_MUL7
: calibration constant for measurement of light output LD8 current
14.2.49. Registers CALIB_VLT_ADD[0:7]
These registers contain calibration constants for measurement of light output voltages.
CALIB_CUR_ADD0
: calibration constant for measurement of light output LD1 voltage
CALIB_CUR_ADD1
: calibration constant for measurement of light output LD2 voltage
CALIB_CUR_ADD2
: calibration constant for measurement of light output LD3 voltage
CALIB_CUR_ADD3
: calibration constant for measurement of light output LD4 voltage
CALIB_CUR_ADD4
: calibration constant for measurement of light output LD5 voltage
CALIB_CUR_ADD5
: calibration constant for measurement of light output LD6 voltage
CALIB_CUR_ADD6
: calibration constant for measurement of light output LD7 voltage
CALIB_CUR_ADD7
: calibration constant for measurement of light output LD8 voltage
14.2.50. Registers CALIB_VLT_MUL[0:7]
These registers contain calibration constants for measurement of light output voltages.
CALIB_CUR_MUL0
: calibration constant for measurement of light output LD1 voltage
CALIB_CUR_MUL1
: calibration constant for measurement of light output LD2 voltage
CALIB_CUR_MUL2
: calibration constant for measurement of light output LD3 voltage
CALIB_CUR_MUL3
: calibration constant for measurement of light output LD4 voltage
CALIB_CUR_MUL4
: calibration constant for measurement of light output LD5 voltage
CALIB_CUR_MUL5
: calibration constant for measurement of light output LD6 voltage
CALIB_CUR_MUL6
: calibration constant for measurement of light output LD7 voltage
CALIB_CUR_MUL7
: calibration constant for measurement of light output LD8 voltage
14.2.51. Register CALIB_UNLOCK
This register is intended for entering an unlock code to allow the reprogramming of the various
calibration constants used for measuring the current and voltage on the eight light outputs.