LTDVE8CH-20 – INSTRUCTION MANUAL
45
GEN_DLY_CNT14
: pulse delay setting for generator 15
GEN_DLY_CNT15
: pulse delay setting for generator 16
Allowed values are in the range from 0 (default value) to 1023 (maximum value). Avoid operation
with non-allowed values.
According to the time base selected in register
GEN_DLY_BASE
[x] and the count set in
GEN_DLY_CNT
[x], the pulse delay may be calculated using the following formula:
Delay[x] [µs] = value(GEN_DLY_BASE[x]) * value(GEN_DLY_CNT[x])
The pulse delay may range from 0 µs to 1,023,000 µs with variable absolute resolution.
Bit fields [15:10] of these registers are unused. When writing these bits, they must be set to zero.
14.2.11. Registers GEN_WDT_BASE[0:15]
Each bit field [1:0] of these sixteen registers holds the time base selector for the generation of the
pulse width in the relevant pulse generator.
GEN_WDT_BASE0
: time base selector for generation of pulse width in generator 1
GEN_WDT_BASE1
: time base selector for generation of pulse width in generator 2
GEN_WDT_BASE2
: time base selector for generation of pulse width in generator 3
GEN_WDT_BASE3
: time base selector for generation of pulse width in generator 4
GEN_WDT_BASE4
: time base selector for generation of pulse width in generator 5
GEN_WDT_BASE5
: time base selector for generation of pulse width in generator 6
GEN_WDT_BASE6
: time base selector for generation of pulse width in generator 7
GEN_WDT_BASE7
: time base selector for generation of pulse width in generator 8
GEN_WDT_BASE8
: time base selector for generation of pulse width in generator 9
GEN_WDT_BASE9
: time base selector for generation of pulse width in generator 10
GEN_WDT_BASE10
: time base selector for generation of pulse width in generator 11
GEN_WDT_BASE11
: time base selector for generation of pulse width in generator 12
GEN_WDT_BASE12
: time base selector for generation of pulse width in generator 13
GEN_WDT_BASE13
: time base selector for generation of pulse width in generator 14
GEN_WDT_BASE14
: time base selector for generation of pulse width in generator 15
GEN_WDT_BASE15
: time base selector for generation of pulse width in generator 16
Allowed values are in the range from 0 to 3 and are listed below. Avoid operation with non-listed
values.
When 0x0 a time base of 1 µs is selected (default value)
When 0x1 a time base of 10 µs is selected
When 0x2 a time base of 100 µs is selected
When 0x3 a time base of 1000 µs is selected
Bit fields [15:2] of these registers are unused. When writing these bits, they must be set to zero.