LTDVE8CH-20 – INSTRUCTION MANUAL
50
PRT_CNT_OFF5
: minimum turn-off time for light output LD6
PRT_CNT_OFF6
: minimum turn-off time for light output LD7
PRT_CNT_OFF7
: minimum turn-off time for light output LD8
Allowed values are in the range from 1 (default value) to 1023 (maximum value) and are expressed
in ms, so the minimum turn-off time can range from 1 ms to 1023 ms with a resolution of 1 ms. Avoid
operation with non-allowed values.
Bit fields [15:10] of these registers are unused. When writing these bits, they must be set to zero.
14.2.18. Registers PRT_ENA_OFF[0:7]
Bit 0 of these registers holds the enable flag for the limitation of turn-off time for light outputs LD1,
LD2, LD3, LD4, LD5, LD6, LD7 and LD8.
PRT_ENA_OFF0
: enable flag for the limitation of turn-off time for light output LD1
PRT_ENA_OFF1
: enable flag for the limitation of turn-off time for light output LD2
PRT_ENA_OFF2
: enable flag for the limitation of turn-off time for light output LD3
PRT_ENA_OFF3
: enable flag for the limitation of turn-off time for light output LD4
PRT_ENA_OFF4
: enable flag for the limitation of turn-off time for light output LD5
PRT_ENA_OFF5
: enable flag for the limitation of turn-off time for light output LD6
PRT_ENA_OFF6
: enable flag for the limitation of turn-off time for light output LD7
PRT_ENA_OFF7
: enable flag for the limitation of turn-off time for light output LD8
When set to zero the limitation of turn-off time is disabled (default value), when set to one the
limitation of turn-off time is enabled.
Bit fields [15:1] of these registers are unused. When writing these bits, they must be set to zero.
14.2.19. Registers CUR_RANGE[0:7]
Each bit field [1:0] of these eight registers selects the current range for the relevant light output.
CUR_RANGE0
: current range setting for light output LD1
CUR_RANGE1
: current range setting for light output LD2
CUR_RANGE2
: current range setting for light output LD3
CUR_RANGE3
: current range setting for light output LD4
CUR_RANGE4
: current range setting for light output LD5
CUR_RANGE5
: current range setting for light output LD6
CUR_RANGE6
: current range setting for light output LD7
CUR_RANGE 7
: current range setting for light output LD8
Allowed values are in the range from 0 to 3 and are listed below. Avoid operation with non-listed
values.
When 0x0 the automatic current range mode is selected
When 0x1 the low current range (zero up to 200 mA) is selected