LTDVE8CH-20 – INSTRUCTION MANUAL
49
LD3, LD4, LD5, LD6, LD7 and LD8.
PRT_CNT_ON0
: maximum turn-on time for light output LD1
PRT_CNT_ON1
: maximum turn-on time for light output LD2
PRT_CNT_ON2
: maximum turn-on time for light output LD3
PRT_CNT_ON3
: maximum turn-on time for light output LD4
PRT_CNT_ON4
: maximum turn-on time for light output LD5
PRT_CNT_ON5
: maximum turn-on time for light output LD6
PRT_CNT_ON6
: maximum turn-on time for light output LD7
PRT_CNT_ON7
: maximum turn-on time for light output LD8
Allowed values are in the range from 1 (default value) to 1023 (maximum value) and are expressed
in ms, so the maximum turn-on time can range from 1 ms to 1023 ms with a resolution of 1 ms. Avoid
operation with non-allowed values.
Bit fields [15:10] of these registers are unused. When writing these bits, they must be set to zero.
14.2.16. Registers PRT_ENA_ON[0:7]
Bit 0 of these registers holds the enable flag for the limitation of turn-on time for light outputs LD1,
LD2, LD3, LD4, LD5, LD6, LD7 and LD8.
PRT_ENA_ON0
: enable flag for the limitation of turn-on time for light output LD1
PRT_ENA_ON1
: enable flag for the limitation of turn-on time for light output LD2
PRT_ENA_ON2
: enable flag for the limitation of turn-on time for light output LD3
PRT_ENA_ON3
: enable flag for the limitation of turn-on time for light output LD4
PRT_ENA_ON4
: enable flag for the limitation of turn-on time for light output LD5
PRT_ENA_ON5
: enable flag for the limitation of turn-on time for light output LD6
PRT_ENA_ON6
: enable flag for the limitation of turn-on time for light output LD7
PRT_ENA_ON7
: enable flag for the limitation of turn-on time for light output LD8
When set to zero the limitation of turn-on time is disabled (default value), when set to one the
limitation of turn-on time is enabled.
Bit fields [15:1] of these registers are unused. When writing these bits, they must be set to zero.
14.2.17. Registers PRT_CNT_OFF[0:7]
Each bit field [9:0] of these registers holds the minimum turn-off time for light outputs LD1, LD2,
LD3, LD4, LD5, LD6, LD7 and LD8.
PRT_CNT_OFF0
: minimum turn-off time for light output LD1
PRT_CNT_OFF1
: minimum turn-off time for light output LD2
PRT_CNT_OFF2
: minimum turn-off time for light output LD3
PRT_CNT_OFF3
: minimum turn-off time for light output LD4
PRT_CNT_OFF4
: minimum turn-off time for light output LD5