The Stops section lists the following:
Fan Failure
Detected
A fan has stopped functioning.
Table 7: Reasons for stops
Feeder Jammed
Results when the lower skew detect sensor has been
blocked for a specified period of time. Both the feed
jammed time and feed streaming time define this period.
Upper Skew
Detect Sensor
Blocked
Results when the upper skew detect sensor is blocked by
something when the system is attempting to start up.
Middle Skew
Detect Sensor
Blocked
Results when the middle skew detect sensor is blocked
by something when the system is attempting to start up.
Lower Skew
Detect Sensor
Blocked
Results when the lower skew detect sensor is blocked by
something when the system is attempting to start up.
System Entry
Sensor Blocked
Results when the system entry sensor is blocked by
something when the system is attempting to start up.
Vertical Turn
Sensor Blocked
Results when the vertical turn sensor is blocked by
something when the system is attempting to start up.
Stacker Entry
Sensor Blocked
Results when the stacker entry sensor is blocked by
something when the system is attempting to start up.
Bin 2 Gate
Sensor Blocked
Results when the bin 2 gate sensor is blocked by
something when the system is attempting to start up.
Bin 3 Gate
Sensor Blocked
Results when the bin 3 gate sensor is blocked by
something when the system is attempting to start up.
Bin 4 Gate
Sensor Blocked
Results when the bin 4 gate sensor is blocked by
something when the system is attempting to start up.
Table 6: Reasons for jams (continued)