76
Statistics
AS7200 User Manual - OPEX Corporation use only - not for distribution
Missing Piece at
Straight Through
Path
Results when the piece was supposed to go to the
stacker bypass bin but didn't.
Batch Manager
has an Internal
Error
Results when there is an internal error within Batch
Manager.
Detected a File
Write Error
Results when the software detects a problem with writing
image or batch files to the specified directories.
ScanLink Plug-in
Failed
Results when there is a failure sending information to the
ScanLink plug-in.
ScanLink Plug-in
Requested a Jam
Results when the ScanLink Plug-in has requested a jam.
Host to
Controller Report
Missing
Results when the controller is expecting piece
information from the host and does not receive it within
the expected time window. This is frequently caused by
pushing the system to its limits or by something causing
the system to get out of sync.
Jam Caused by
Reject
Results whenever a reject other than Jamsorts occurs.
Thus every reject other than Jamsorts is counted as a
jam under this category. The Job Parameter "Stop
Machines for Rejects" must be set to something other
than "No" for rejects to jam the machine. Otherwise,
rejects will be directed to the reject bin and processing
will continue.
Double Detected
The Multifeed Sensor indicates that two pieces are being
fed together.
MFD Skew Angle
Exceeded Sensor
Blocked
The MFD Skew Angle Exceeded Sensor is blocked.
MFD Skew
Damage
Exceeded Sensor
Blocked
The MFD Skew Damage Exceeded Sensor is blocked.
Table 6: Reasons for jams (continued)