LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL
16
EN
EN
2
Index:
1- Limitations of use
2- General description
3- Technical data
4- Description of the control panel
5- Diagram of the electrical system
6- Wirings description.
7- Wiring of the outputs:
7.1- Power line, flashing light, electric motor
7.2- Accessory power supply output
8- Wiring of the inputs
8.1- Sequential buttons
8.2- Open button
8.3- Photocell while closing
8.4- Safety edge
8.5- Antenna connection
9- Complete electrical connection diagram
10- Description of the buttons on the control panel
11- Description of the LEDs on the control panel
12- Description of the trimmer
13- Description of the dip switch
14- Automatic Programming
15- Remote controls storage
15.1- Remote control storage associated with the Start input
15.2- Remote control storage associated with the Pedestrian input
15.3- Cancelling all programmed remote controls
16- Manual programming
17- Automatic reclose programming
19- Return to defaut
20- User manual
21- Declaration of conformity
1
LIMITATIONS OF USE
: the EC1 control panel was designed to control the operation of 230VAC electro-mechanical actuators
for the automation of sliding gates. Any other use is considered improper and potentially dangerous. It is forbidden to put the
product to any uses other than the intended one. It is forbidden to tamper with or make changes to the product. On Automation
S.r.l. cannot assume responsibility for failure to observe these requirements.
General description
The control panel can control geared motors of a power not exceeding 600 W for each motor output, and is also equipped with:
-input diagnostics LED
-integrated receiver programmable with a max of 8 remote controls
-torque adjustment
-obstacle detection
-dedicated balanced input for safety edges
-dedicated open only input for magnetic induction loops or timers
- pedestrian with remote control