LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL
22
EN
11
10
11-
DESCRIPTION OF THE LEDS ON THE CONTROL PANEL
CODE
DESCRIPTION
COLOUR
START
Shows the status of the START input (terminal number 1) off with the input not engaged; contact normally
open.
Red
STOP
Shows the status of the STOP input (terminal number 2) on with the input not engaged; contact normally
closed.
Red
PHC
Shows the status of the EXTERNAL PHOTOCELL PHC input enabled only during closing (terminal num-
ber 4) on with the input not engaged; contact normally closed.
Red
EDGE
Shows the status of the SAFETY EDGE EDGE input enabled during opening and closing (terminal number
5) on with the input not engaged; contact normally closed.
Red
DL7
Shows the status of the LIMIT SWITCH input (terminal number 9) contact normally closed.
Red
DL8
Shows the status of the LIMIT SWITCH input (terminal number 10) contact normally closed.
Red
DL2
Indicates faults or status during programming
Red
10-
Description of the buttons on the control panel
Code
Description
SET
Button for programming the stroke
SET TX
Button for programming and cancelling the remote
12
13
DESCRIPTION OF THE TRIMMER
Code
Description
FORZA
Regulates the force of the motor;
turn the trimmer clockwise to increase the force.
DESCRIPTION OF THE DIP SWITCHES
Code
Status
Description
DSW1-1
OFF
Community feature OFF (SEQ button working if the gate is opening)
DSW1-1
ON
Community feature ON (any other SEQ and Pedestrian controls are ignored if the gate is already opening)
DSW1-2
OFF
Soft start function not enabled, the geared motor starts at maximum power.
DSW1-2
ON
Soft start function activated.
DSW1-3
OFF
Closing after disengaging of photocell input not enabled
DSW1-3
ON
Closing after 1,5 second disengaging of photocell input enabled
DSW1-4
OFF
Without encoder
DSW1-4
ON
With encoder
WARNING: THE DIP SWITCHES MUST BE MODIFIED WITH THE GATE FULLY CLOSED, OTHERWISE TURN OFF THE
POWER SUPPLY, SET THE DIP SWITCHES AND THEN TURN THE POWER ON AGAIN..
0
100
POWER
50
%
ON
1 2 3 4