Technical data:
before installing the product, check that the area of installation is compatible with the temperature limits.
Key:
1- Terminal block for connecting the power supply of the con-
trol panel
2- Terminal block for connecting the motor power supply
output, and the flashing light output
3- Terminal block for connecting the safety device control
inputs and outputs at 24VDC
4- Terminal block for connecting the antenna
5- Radio module
6- Terminal block for connecting the encoder
7- Terminal block for connecting the limit switches
8- Input diagnostics LED limit switches
9- Transformer
10- Input diagnostics LED
11- Button for programming the gate and store or delete the
remote control
12- Trimmer to adjust force
13- Dip switch for programming the logical functions
14- Programming diagnostics LED
15- Fuse for the output of the electric motors, flashing lihgt
and transformer (5 A)
16- Input diagnostics LED encoder
3
DESCRIPTION
VALUE
Power supply of the control panel
230 V AC +6% -10 % /50 HZ
Power supply of the motor
6% -10 % maximum power 500W
Power supply of the flashing light
230VAC for a maximum of di 100W
Power supply for external devices
24VDC +10% -15%
Max current for external devices
350 mA
Maximum power consumption
12 W
Motor protection
5 A (F2) fuse
Operating temperature range
- 20 to +70 °C
IP
IP 56
4
DESCRIPTION OF THE CONTROL PANEL
EN
7
F2
25
26
ON
1 2 3 4
SW1
SET TX
SET
PROG
START
STOP
EDGE
M1
M5
1
2
3
4
5
6
8
9
10
DL7
START
STOP
PH1
EDGE
COM
+AS
-AS
POWER
100
0
50
%
ENC
CN3
OPL
COM
CLL
22
23
N
F
DL8
1
2
3
4
5
6
7
8
9
10
11 12 13
14
14
13
12
11
MCL
MOP
MCOM
FLASH
15
FLASH
24
FOTO
15
16