5-52
5-10 User Parameters
5
Operating Functions
Select the FIR filter time constant used for the command pulses (FIR: Finite impulse response).
The higher the setting, the smoother the command pulses.
Control Cycles with High-response Position Control (Pn02 = 0):
Setting: 0, Cycle: (0 + 1)
×
166 = 166
µ
s
Setting: 1, Cycle: (1 + 1)
×
166 = 332
µ
s
Setting: 31, Cycle: (31 + 1)
×
166 = 5312
µ
s
Control Cycles with Advanced Position Control (Pn02 = 2):
Setting: 0, Cycle: (0 + 1)
×
333 = 333
µ
s
Setting: 1, Cycle: (1 + 1)
×
333 = 666
µ
s
Setting: 31, Cycle: (31 + 1)
×
333 = 10656
µ
s
Pn4E
Smoothing Filter Setting
Setting range
0 to 31
Unit
---
Default setting
0
Power OFF
→
ON
Yes
Position
t
f
= (Pn4E + 1)
×
Control cycle
Input position command
t
f
Position command after
smoothing filter processing
t
f
Time
Position command after FIR filter processing
Command
t
f
t
f
Response with position loop gain
Response with position
loop gain
Pn4F
Not used. (Do not change setting.)