5-10 User Parameters
5
Operating Functions
If the Gain Switching Input Operating Mode Selection (Pn30) is set to 1 (gain switching enabled),
set the phased switching time only for position loop gain at gain switching.
The switching time is set only when switching from a small position loop gain to a large position
loop gain (Kp1 to Kp2). This is to reduce the shock to the machine due to sudden changes in the
gain.
Set a value smaller than the difference between Kp2 and Kp1.
This parameter is automatically changed by executing realtime autotuning function. To set it
manually, set the Realtime Autotuning Mode Selection (Pn21) to 0.
Pn35
Position Loop Gain Switching Time
Setting range
0 to 10000
Unit
(S 1)
(
×
166
µ
s)
Default setting
20
Power OFF
→
ON
---
Position
Kp1 (Pn10) < Kp2 (Pn18)
0
0
1
1
2
2
3
3
Pr35 =
Kp2 (Pn10)
166
166
166
166
µ
s
Kp1 (Pn18)
Example:
Bold solid line
Thin solid line
Gain 1
Gain 2
Gain 1
Pn36
Not used. (Do not change setting.)
Pn37
Not used. (Do not change setting.)
Pn38
Not used. (Do not change setting.)
Pn39
Not used. (Do not change setting.)
Pn3A
Not used. (Do not change setting.)
Pn3B
Not used. (Do not change setting.)
Pn3C
Not used. (Do not change setting.)
Pn3D
Not used. (Do not change setting.)
Pn3E
Not used. (Do not change setting.)
Pn3F
Not used. (Do not change setting.)
Содержание R7D-BP
Страница 18: ......
Страница 26: ......
Страница 138: ......
Страница 176: ......
Страница 238: ......
Страница 264: ......
Страница 290: ......
Страница 310: ......
Страница 311: ...Connection Examples Appendix 1 Appendix...
Страница 321: ......
Страница 324: ......
Страница 326: ......
Страница 327: ......