5-39
5-10 User Parameters
5
Operating Functions
These parameters are for the gain and time constants selected when gain switching is enabled in
the Gain Switching Input Operating Mode Selection (Pn30).
The gain is switched according to the condition set in the Gain Switch Setting (Pn31).
If the mechanical system inertia changes greatly or if you want to change the responsiveness while
the Servomotor is rotating and stopped, you can achieve the appropriate control by setting the
gains and time constants beforehand for each condition, and switch between them according to
the condition.
These parameters are automatically changed by executing realtime autotuning function. To set
them manually, set the Realtime Autotuning Mode Selection (Pn21) to 0.
Gain switching function is enabled only for position control. For Internally Set Speed Control,
operation will be performed using gain 1 (Pn11, Pn12, Pn13, and Pn14).
Set the notch frequency of the resonance suppression notch filter.
Set this parameter to approximately 10% lower than the resonance frequency of the mechanical
system.
The notch filter function will be disabled if this parameter is set to 1500.
Set the width to one of five levels for the resonance suppression notch filter.
Increasing the setting increases the width.
Normally, use the default setting.
Pn18
Position Loop Gain 2
Setting range
0 to 32767
Unit
1/s
Default setting
20
Power OFF
→
ON
---
Pn19
Speed Loop Gain 2
Setting range
1 to 3500
Unit
Hz
Default setting
80
Power OFF
→
ON
---
Pn1A
Speed Loop Integration Time Constant 2
Setting range
1 to 1000
Unit
ms
Default setting
50
Power OFF
→
ON
---
Pn1B
Speed Feedback Filter Time Constant 2
Setting range
0 to 5
Unit
---
Default setting
0
Power OFF
→
ON
---
Pn1C
Torque Command Filter Time Constant 2
Setting range
0 to 2500
Unit
×
0.01 ms
Default setting
100
Power OFF
→
ON
---
Pn1D
Notch Filter 1 Frequency
Setting range
100 to 1500
Unit
Hz
Default setting
1500
Power OFF
→
ON
---
Position
All modes
All modes
All modes
All modes
All modes
Pn1E
Notch Filter 1 Width
Setting range
0 to 4
Unit
---
Default setting
2
Power OFF
→
ON
---
All modes
Pn1F
Not used. (Do not change setting.)
Содержание R7D-BP
Страница 18: ......
Страница 26: ......
Страница 138: ......
Страница 176: ......
Страница 238: ......
Страница 264: ......
Страница 290: ......
Страница 310: ......
Страница 311: ...Connection Examples Appendix 1 Appendix...
Страница 321: ......
Страница 324: ......
Страница 326: ......
Страница 327: ......