33
F3SJ-A
User’s Manual
Chapter
2
Ba
si
c Sys
te
m
System Configuration and Functions
E
Ton: Response time of safety output's OFF to ON, Toff: Response time of safety output's ON to OFF
See p.17 for response time
Setting Change by the Setting Tool
Output operation mode and other attributes can be changed for the auxiliary output by the setting tool.
Auxiliary Output (Non-Safety Output) p.94
Resetting Lockout
When the cause of the lockout is removed, the lockout condition can be released by using either of the
following methods.
•Cycle the power back ON
•Reset input
For manual reset, apply 0 to 1.5V to the reset input line for 100ms or longer, and then open the switch
to apply a 9 to 24V signal or open circuit (pin 4/yellow).
For auto reset, set the reset line open or to 9 to 24V for 100ms or longer, and then apply 0 to 1.5V
again (pin 4/yellow).
Lockout due to an interlock wiring error and an ABC blinking error may not be released by a reset input.
ON
OFF
ON
OFF
Toff
/Blocked
Unblocked
Blocked
Unblocked
Auxiliary output 1
Safety output
Toff
x2 or less *1
Ton
Toff x2 or less *1
*1 When a reversed signal of safety output is assigned to the auxiliary output 2 by the setting tool,
a delay time of the auxiliary output 2 from the safety output is Toff x 3 or less.
Содержание F3SJ Series
Страница 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Страница 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Страница 20: ...xviii Introduction Contents F3SJ A User s Manual...
Страница 44: ...24 Chapter 1 Compatibility with former version F3SJ A User s Manual Overview and Specifications...
Страница 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Страница 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...