49
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
Timing Chart
*1 The value is applied to a single sensor. Values for connected sensors are:
•T1min: Muting input time limit (minimum value)
This is set to 0.03 sec., the minimum value for the input time difference between muting input 1 and 2.
A muting error occurs when the input time difference between muting input 1 and 2 is less than this
value.
•T1max: Muting input time limit (maximum value)
This is set to 3 sec., the maximum value for the input time difference between muting input 1 and 2.
•T2: Muting time limit
This is set to 60 sec., the muting function continuation time. When this muting state exceeds this time,
muting is released.
•T3: Muting input time with allowable waveform cracks
This is the maximum value for the waveform cracks allowed for muting input 1 and 2 when muting is
in effect. It is set to 0.1 sec.
# of connections
*1 Value (s)
Single
0.15
2 connected
0.26
3 connected
0.29
4 connected
0.32
OFF
Safety output
ON
OFF
Blinking
OFF
Blocked
Unblocked
ON
OFF
ON
ON
OFF
ON
OFF
Enabled
Disabled
T3(0.1s ) max.
T3(0.1s ) max.
T3(0.1s ) max.
T3(0.1s ) max.
T2 max.
0.15s max. *1
Muting lamp
(External indicator)
F3SJ Unblocked
/Blocked
Muting sensor A1
Muting sensor B1
Muting sensor A2
Muting sensor B2
Muting state
T1min to T1max
Содержание F3SJ Series
Страница 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Страница 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Страница 20: ...xviii Introduction Contents F3SJ A User s Manual...
Страница 44: ...24 Chapter 1 Compatibility with former version F3SJ A User s Manual Overview and Specifications...
Страница 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Страница 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...