What can be done by the setting tool
E
3. Position Detection Muting Mode
• Muting Zone Setting
Setting tool provides designation of beams for muting. (All beams are specified for factory shipment)
You can specify a beam by teaching, with which the sensor learns muting beams as those interrupted,
or manually.
Muting Zone Setting Example
•Setting from F3SJ’s upper beams (figure 1)
•Setting multiple zones (figure 2)
- Only one zone can be configured as a muting zone by the setting console, which cannot set more than one zone.
- Interlock function is disabled for a muting system.
If you want to use start or restart interlock, use the setting tool to enable the function.
- When muting function is enabled, a muting lamp is turned on to notify people in the surrounding zone that the safety
functions are disabled. Factory setup is external indicator outputs 1 and 2.
While the setting tool allows change of output destination for a muting lamp, muting/override information must be set
to at least one of auxiliary output 1 or external indicator outputs 1 or 2.
If none of the above output is set, F3SJ enters lockout.
- Auxiliary output 1, external indicator outputs 1 and 2 have diagnosis function.
For safety reason, using diagnosis function is recommended.
- Auxiliary Output (Non-Safety Output) p.94
- External Indicator Output (Non-Safety Output) p.98
1. Standard Muting Mode
Operation mode configured for F3SJ factory shipment.
Turning muting inputs 1 and 2 ON with time difference enables muting function.
For details, see Muting in Chapter 2.
Setting can be changed, such as muting time limit.
2. Exit Only Muting Mode (Setting is Available Only for PC Tool For F3SJ)
Turning muting inputs 1 and 2 ON with time difference enables muting function.
Difference from standard mode exists in muting completion condition.
Lower
Upper
Lower
Upper
Muting zone
Muting zone
Muting zone
Normal detecting beam
Muting beams
Figure 1
Figure 2
Содержание F3SJ Series
Страница 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Страница 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Страница 20: ...xviii Introduction Contents F3SJ A User s Manual...
Страница 44: ...24 Chapter 1 Compatibility with former version F3SJ A User s Manual Overview and Specifications...
Страница 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Страница 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...