47
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
3.
The muting sensors are blocked and the safety function of the F3SJ is disabled
Muting sensors A1 and B1 are turned OFF but A2 and B2 are ON, so the muting function is still
working. Safety outputs 1 and 2 are turned ON.
4.
The muting function is released
Muting sensor A2 is turned OFF and the muting function is released, and the safety function of the
F3SJ is working.
Installation Distance
The minimum distances, D2 [ m ] and D3 [ m ], required for the muting sensors to keep the muting
function enabled are
D2
<
L . . . . . Formula (3)
D3
<
L . . . . . Formula (4)
L [ m ] : Length of a workpiece
The maximum distance, d2 [ m ], required for muting sensors to keep the muting function enabled is
V x T1min
<
d2
<
V x T1max . . . . . Formula (5)
V [ m/s ] : Approach speed of a workpiece
T1min [ s ] : Muting input time limit value (minimum). 0.03s.
T1max [ s ] : Muting input time limit value (maximum). 3s.
A1
F3SJ
B2
B1
A2
Workpiece
Hazardous zone
A1
B1
F3SJ
A2
B2
Workpiece
Hazardous zone
Содержание F3SJ Series
Страница 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Страница 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Страница 20: ...xviii Introduction Contents F3SJ A User s Manual...
Страница 44: ...24 Chapter 1 Compatibility with former version F3SJ A User s Manual Overview and Specifications...
Страница 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Страница 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...