47
I/O Data Allocations
Section 4-3
Inputs
I/O
Word address
Bit No.
Type
Bit name
Description
Head 1 of CS1W-
V600C11, CS1W-
V600C12, CJ1W-
V600C11, or
CJ1W-V600C12
Head 2 of CS1W-
V600C12 or
CJ1W-V600C12
Input
n + 7
n + 17
15
Unit
Status
Unit Busy Flag
Turns ON when there is an ID Sensor Unit
error.
14
Test Mode Flag
Turns ON during Test Mode.
13
Head Power Sup-
ply Error Flag
Turns ON when there is an error in the
Unit’s 24-V power supply or the input power
supply.
12
Memory Error
Flag
Turns ON when there is an error in ID Sen-
sor Unit memory.
03 to 11
---
Not used
02
Error End Flag
ON for one scan when processing ends in
an error.
01
Normal End Flag
ON for one scan when processing ends nor-
mally.
00
ID Busy Flag
Turns ON while communications are in
progress.
Содержание CJ - 12-2004