99
ID Sensor Unit Alarms
Section 7-2
Error name
Word
(n + 8)
Word
(n + 9)
Error
Correction
Data Carrier commu-
nications error
Bit 12
E070
An error occurred in communications
with a Data Carrier, preventing a nor-
mal end.
Check for excessive noise.
Check the travel speed.
Check the distance between the Head
and Data Carrier.
Data Carrier verifica-
tion error
Bit 14
E071
The correct data could not be written to
the Data Carrier.
(Occurs only when verification is set for
a write operation.)
Check the travel speed. (Page 92)
Check for excessive noise.
Data Carrier missing
error
Bit 10
E072
The communications specification was
for a trigger, but there was no Data
Carrier in the communications area.
The communications specification was
for single auto, but the auto wait time
expired.
The Head and Data Carrier are too far
apart.
The axis is out of alignment.
Status Flag
Bit 04
E076
An overflow or underflow occurred for a
Calculation Write command.
The data did not verify for a Data
Check command.
The number of writes was exceeded for
a Number of Writes Control command.
An error occurred while writing for a
Copy command.
Check the data settings.
Replace the Data Carrier.
Make the same checks as for a com-
munications error.
Data Carrier address
error
Bit 13
E07A
The Data Carrier address is not cor-
rect.
Specify the address correctly.
Do not allow processing for the Bit Set,
Bit Clear, Mask Bit Write, Calculation
Write, or Number of Writes Control
command to exceed one page. (Page
59)
Battery low warning
Bit 05
E07B
The life of the battery built into a SRAM
Data Carrier has expired.
Replace the Data Carrier.
Head error
Bit 15
E07C
A R/W Head error occurred.
Check 24 V DC input.
(CS1W-V600C12 only)
Check the R/W Head.
Write protection error Bit 11
E07D
An attempt was made to write to a
write-protected area.
Specify the address and number of
bytes correctly.
Clear write protection. (Page 61)
Data storage area
specification error
Bit 01
No
change
The data storage area specification is
not correct.
Specify the data storage area specifi-
cation correctly.
Command error
Bit 00
No
change
The command to the ID Sensor Unit is
not correct.
Specify the command correctly.
Содержание CJ - 12-2004
Страница 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Страница 3: ...iv...
Страница 11: ...xii...
Страница 55: ...36 Connections and Wiring Section 3 4...
Страница 69: ...50 I O Data Allocations Section 4 3...
Страница 91: ...72 Data Check Section 5 7...
Страница 141: ...122 Sample Programming Appendix B...
Страница 147: ...128 Revision History...