112
Sample Programming
Appendix B
First word allocated to Unit in DM Area: m = (100
×
(0 + 1)) = D20100
First word allocated to Unit in CIO Area: n = CIO 2000 + (10
×
(0 + 1)) = CIO 2010
---: Ignored.
DM
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
D20100
0
0
0
0
Not used
Communications
test switch enabled
Verification for writ-
ing
Communications
mode: Distance
D20101
0150
Auto Wait Time Setting
Word
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CIO 2011
0
0
2
1
Command code
Communications
specification
Data order
CIO 2012
00
10
First read address
CIO 2013
00
0A
Number of read bytes
CIO 2014
10
00
Read data storage location (rightmost 4 digits)
CIO 2015
5
0
00
Data storage area
Bank designation
Read data storage location (leftmost 2
digits)
CIO 2016
00
00
---
Содержание CJ - 12-2004