15
Operating Procedure
Section 2-2
Initial Settings
1,2,3...
1.
Make the settings in the words allocated to Special I/O Units in the DM
Area (refer to page 41).
First word allocated to Unit in DM Area: m = (100
×
0) = D20000
2.
PLC Power Supply OFF and ON (or turn ON the Unit Restart Bit)
Ladder Programming
Set the Command, Communications Specification, Read Data Storage Or-
der, First Data Carrier Read Address, Number of Bytes to Read, and Read
Data Storage Destination in words (n + 1) to (n + 6) allocated in the Special
I/O Unit Area (here, CIO 2001 to CIO 2006).
Peripheral port
Programming Console
DM
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
D20000
0
0
0
0
Not used
Communications
test switch enabled
Verification for writ-
ing
Communications
mode: Distance
D20001
0000
Auto Wait Time Setting: Infinite
Peripheral port
Programming Console