RS-485 and RS-232 Interfaces
Connection of auxiliary equipment (CAN-Log, PP-01 passenger sensors, DV-1 driver
display, JPEG camera, data reception from vehicle J1708 data bus, reception and
transmission of navigation data as per NMEA standard) is carried out through RS-485
and RS-232 interfaces. When needed, it is recommended to use the RS-232 to RS-485
converter.
In the “Settings” window open the “Inputs” tab:
For RS-485 and RS-232 interfaces choose the setting:
“Disabled” – interface is not used
“Omnicomm LLS” – use to connect Omnicomm LLS fuel level sensors
“Omnicomm LLS / LLD” – use to connect Omnicomm LLS fuel level sensors or
Omnicomm LLD fuel volume indicator
“ALM Weight Indicator” – use for connection to the axle load monitoring device
“CAN-Log” – connection to a CAN-log device
“J1708” – connection to the vehicle J1708 data bus
“NMEA reception” – use of navigation data from an external device. If you select
this option, you must specify the data port bit rate. “RS port bit rate for NMEA data”
– select the data port bit rate for reception of navigation data from an external
device
“NMEA transmission” – use the Terminal navigation data in an external device
“PP-01” – use for connection of the passenger throughput sensor
“Camera” – use for the digital camera connection
“DV-01” – use for the driver display connection
Auxiliary Equipment
Omnicomm OKO video terminal
38