“Data source” – select the data to register ignition on/off. Possible options:
“Ignition key” – the ignition on/off is registered on the position of the key upon direct
connection to the ignition key.
“Voltage” – the ignition on is registered upon reaching the vehicle network power
supply threshold voltage. Specify the value “Threshold voltage, V” – the value of the
vehicle network power supply voltage, upon reaching which the ignition on will be
registered. Ignition off is registered, when the voltage drops to 0.5 V below the
threshold.
Selection of Speed Source
In the “Settings” tab select the “Inputs” section from the list.
In the “Vehicle speed” section:
“Data source” – select the data to process the speed values. Possible options: “GPS”,
“CAN bus”
Engine RPM
In the “Settings” tab select the “Inputs” section from the list.
In the “The engine revolutions” section:
“Data source” – select the signal type. Possible values:
«Disabled»
«Ignition key»
«CAN bus»
«RPM input»
Connect the tachometer to the Terminals according to the diagram:
Operation Parameters Setting
Omnicomm OKO video terminal
21