Omnicomm OKO Скачать руководство пользователя страница 25

5. Refresh the page or restart the browser

6. You will be prompted to enable the Active X add-on:

7. Press “Allow”

The browser will be configured only once, ie.exe reinstallation is not required.

Omnicomm OKO video camera setting

Each video camera is connected and configured individually in turns. Only one
camera may be connected at a time.

1. Switch on the Omnicomm OKO video terminal power

2. Connect the video terminal to a PC via Ethernet interface using a LAN adapter and a
patch cord delivered with the video terminal

3. Connect the video camera to any video terminal connector (“CAM1” – “CAM4”)

4. In your browser, enter the video camera configuration interface address –
192.168.12.241

In the “Account” and “Password”, enter “admin”.

Press the “Log in” button.

Operation Parameters Setting

Omnicomm OKO video terminal

25

Содержание OKO

Страница 1: ...Omnicomm OKO video terminal User Manual 17 12 2018...

Страница 2: ...ng Overview 13 Omnicomm Configurator 13 Remote Configuration Server RCS 14 Operation Parameters Setting 16 GPRS connection 16 Connection to Communication Servers 16 Data Collection 17 Data Trensmissio...

Страница 3: ...rminal Restart 34 Setting Password on Configuration Changing 34 Data Collection and Transmission Blocking 35 Remote Configuration Server Operation Setting 35 Terminal SIM Card Number Identification 36...

Страница 4: ...Panic Button and GSM Call Button 56 CAN Bus 58 Sealing 60 Technical Specifications 61 LED indication 65 SMS Commands 66...

Страница 5: ...equiring video recording determination of location speed and movement direction of the vehicle reading and filtering values from fuel level sensors and a wide range of connected equipment remote contr...

Страница 6: ...arp pointed object press the button at the SIM1 of SIM2 connector side The SIM card holder will eject 3 Remove the SIM card holder from the connector slots and insert the SIM card into it with contact...

Страница 7: ...ector 1 No of pin Nameof signal Designation Wire color in cable 1 Vehicle power supply voltage Power Red 2 Ground for power Ground power White 3 Output 1 Output 1 Yellow red 4 Universal input 5 Input...

Страница 8: ...r supply voltage Power Red 12 Ground for power Ground signal White 13 RPM input Tachometer Blue 14 Ignition key IGN Yellow 15 Universal input 1 Input 1 Black 16 GSM activation button GSM Green black 1...

Страница 9: ...ersal input 4 Input 4 Black yellow 4 Output 2 Output 2 Yellow blue 5 External sensor power supply Ground LLS White 6 iButton iButton Pink red 7 Line RS 232 Tx Tx RS 232 Grey 8 Universal input 3 Input...

Страница 10: ...M1 CAM2 CAM3 CAM4 No of pin Name of signal Colour of wire 1 RX White green 2 RX Green 3 TX White orange 4 DC Blue 5 DC White blue 6 TX Orange 7 DC White brown 8 DC Brown Installation OmnicommOKO video...

Страница 11: ...Connect Omnicomm OKO video terminals as per diagrams without a ground disconnect switch after the ground disconnect switch Do not connect the terminal before the ground disconnect switch Installation...

Страница 12: ...de the vehicle cabin or in specially equipped electrics boxes on the vehicle protected from atmospheric precipitation Drill 4 mounting holes 5 5 mm Install the video terminal and fix with self tapping...

Страница 13: ...ce 2 Remove protective film from the double adhesive tape on the surface of antenna 3 Attach the antenna with the adhesive side to the installation site 4 Fix the antenna while the adhesive is setting...

Страница 14: ...the setting up completion Remote Configuration Server RCS To connect to the configuration server open the browser and in its address bar enter the address http config omnicomm ru 9911 en A window will...

Страница 15: ...enter the video terminal identification number 2 In the Password field enter the password set in the video terminal during its setting using Omnicomm Configurator 3 Press the button SettingOverview Om...

Страница 16: ...in and password are provided with the SIM card of a number of mobile network operators Connection to Communication Servers Terminals support data transmission to two Communication Servers CS through O...

Страница 17: ...mm or EGTS Data Collection In the Settings tab select the Connection section from the list In the Datacollection parameters section Collection timer set the value of the period of Terminal requesting...

Страница 18: ...the set mode the data are acquired from the particular modules and external devices Adaptive data collection on turns enable disable adaptive data collection on turns which allows increasing the accu...

Страница 19: ...S section SMS enable disable the commands reception via SMS and sending the information messages by the Terminal SMS destination number enter the phone number to which the SMS will be sent with inform...

Страница 20: ...able cellular networks Forbidden the terminal will not transmit data while being in roaming Always in a home network the terminal will transmit data as set up for connection to the CS in a home networ...

Страница 21: ...n will be registered Ignition off is registered when the voltage drops to 0 5 V below the threshold Selection of Speed Source In the Settings tab select the Inputs section from the list In the Vehicle...

Страница 22: ...e Omnicomm OKO video terminal power 2 Connect the video terminal to a PC via Ethernet interface using a LAN adapter and a patch cord delivered with the video terminal 3 Open the adapter network settin...

Страница 23: ...5 Select Internet Protocol Version 4 TCP IPv4 press Properties and set the following configuration OperationParameters Setting OmnicommOKO video terminal 23...

Страница 24: ...inal connector CAM1 CAM4 2 Open Internet Explorer and enter the camera configuration address By default 192 168 12 241 3 A window will open to confirm ie exe installation 4 Press OK and follow the ins...

Страница 25: ...ne camera may be connected at a time 1 Switch on the Omnicomm OKO video terminal power 2 Connect the video terminal to a PC via Ethernet interface using a LAN adapter and a patch cord delivered with t...

Страница 26: ...en several cameras are connected to the video terminal their IP addresses must be different Omnicomm OKO video terminal setting 1 Connect the OKO video terminal to a PC using a mini USB USB cable 2 Ru...

Страница 27: ...h cord with RJ 45 connector using a crimper as per the CAM pins assignment shown in Connector Pin Assignment 3 At the Omnicomm OKO video terminal side Pass the patch cord through the connector as show...

Страница 28: ...atch cord of required length with RJ 45 connectors on both sides using a crimper Connect the camera to the video terminal Perform connection according to the diagram Driving Safety Control In the Sett...

Страница 29: ...ns of the road When selecting manual calibration in the Terminal position field select one of 24 positions as shown in figure Arrow indicates the location of the video terminal s X1 connector The Omni...

Страница 30: ...maximum permissible speed without triggering dangerous driving registration Possible values from 0 to 300 s Default value 15 s Engine speed RPM engine RPM monitoring Threshold enter the maximum permi...

Страница 31: ...istration of dangerous driving Speed and threshold exceeding of potential UI1 Threshold enter the value of speed which exceeding will trigger registration of dangerous driving if universal input No 1...

Страница 32: ...to upon triggering enable digital camera photo sending upon registration of accident Axleload enable disable control of vehicle axle load and total vehicle load Data source displays the axle load data...

Страница 33: ...upon exceeding which an event will be registered Sound notification enable disable sound notification if thresholds of monitored parameters are exceeded Events enable disable event sending to Omnicom...

Страница 34: ...Service menu select Restart Terminal Setting Password on Configuration Changing In the Settings tab select the Additionalequipment section from the list In the Configuring apassword section If you nee...

Страница 35: ...gs tab select the Connection section from the list In the Blocking of information collection and transfer section To block the terminal data acquisition and transmission in the Lock field select Switc...

Страница 36: ...its and letters Terminal SIM Card Number Identification The terminal SIM card telephone number is automatically displayed in the Remote Configuration Server after the second connection to the RCS SMS...

Страница 37: ...Send value of 1 Wire sensor instead of UI select the number of the universal input for displaying the temperature values in Omnicomm Online Auxiliary Equipment OmnicommOKO video terminal 37...

Страница 38: ...e to connect Omnicomm LLS fuel level sensors or Omnicomm LLD fuel volume indicator ALM Weight Indicator use for connection to the axle load monitoring device CAN Log connection to a CAN log device J17...

Страница 39: ...ion to the server iQFreeze use for connection of the refrigerator control device Modbus Struna PMP 201 use for connection to the level gauge PMP 201 or the Struna system TPMS Pressure Pro only for RS...

Страница 40: ...cify the number of sensors connected to the terminal When choosing LLS fuel level sensors connected to a universal input you need to configure the universal input For automatic configuration of the un...

Страница 41: ...performed according to the diagram Connect Omnicomm LLS fuel level sensor according to the diagram Connect several Omnicomm LLS AF sensors to the video terminal one by one starting with 1 universal i...

Страница 42: ...to OmnicommLLDindicator section Data source select the data source to display the value on the Omnicomm LLD indicator Possible options GPS speed displays the vehicle speed Universal input displays th...

Страница 43: ...00 0 to 999 9 engine hours If the number of engine hours is more than 1000 the last three significant figures are displayed and one symbol after the decimal point Engine hours are fully recorded in th...

Страница 44: ...it is recommended to use the RS 232 to RS 485 converter To read the DDD files from the Continental tachograph in Omnicomm Configurator configure the RS 232 or RS 485 interface of the terminal Univers...

Страница 45: ...llector type sensors or contact sensors Coefficient of impulse enter the calibration factor converting the number of pulses to the determined physical quantity Number of pulses from the input in Omnic...

Страница 46: ...acts or contacts closing on commission of any action Current voltage value of the voltage at the universal input of the terminal Current value of measured parameter auxiliary equipment switched on or...

Страница 47: ...imit switches sensors triggered by excess pressure or temperature etc or an additionally mounted sensor as the contact sensor We recommend that you first check the possibility of connection to a stand...

Страница 48: ...measured by the sensor in the units of measurement of this value Voltage corresponding to the maximum value set the value of voltage corresponding to the maximum measured value Current voltage at univ...

Страница 49: ...pe sensors or contact sensors Current value of measured parameter current measured value Equipment name enter the monitored parameter name Driver Identification In the Settings tab select the Identifi...

Страница 50: ...om the readout device after which the second digital output will be disabled Possible values from 0 to 3600 seconds If necessary enable disable the sound reminder of the driver s authorization in the...

Страница 51: ...d emitter on the prepared surface and fix RFID Reader Devices Connection Terminal supports connection of swipe card reader devices via 1 Wire physical interface The connected reader device must fully...

Страница 52: ...0 12 using a milling cutter or a drilling bit and install a push to talk key adapter 3 Fix the push to talk key adapter on the surface with self tapping screws 4 Connect the push to talk key connector...

Страница 53: ...tab select the Outputs section from the list Rule priority set the priority of the rule When at the same time several rules apply a rule with the highest priority is used Possible options 1 highest 2...

Страница 54: ...evant for events because for states fulfillment of this condition would lead to indefinite cycle repeating When selecting the number of cycles specify Delay before closing specify the time until the o...

Страница 55: ...PS available Number of closed open cycles Continuous If the vehicle is outside the geofence and the GPS module data are valid the output will be enabled until the moment of entering the geofence or GP...

Страница 56: ...ress the Import button and select the xml file with geofence settings The geofence name must be not more than 8 character long and consist of symbols digits and Latin letters Geofence should not conta...

Страница 57: ...pressing Connect the panic button according to the diagram Connect the GSM response button to video terminals according to the diagram Auxiliary Equipment OmnicommOKO video terminal 57...

Страница 58: ...which value shall be displayed in Omnicomm Online and check the corresponding boxes in the Use column If you need to add parameters for reading from the CAN bus which are not on the list press the Add...

Страница 59: ...this parameter from the CAN bus Press the Save button The connection to the vehicle CAN bus should be performed via the concatless CAN reader CAN crocodile When using contactless CAN readers the conne...

Страница 60: ...t data during pounding mode Otherwise the fuel level graphic will not be displayed correctly Sealing Protective cover sealing is provided for Omnicomm OKO video terminals Apply the sealing sticker to...

Страница 61: ...mber of SIM cards 2 Video Number of connected IP video cameras From 1 to 4 Video compression format h264 Video encryption Yes Video volume from one camera 5 Mb min Record quality 1024 kbit s Video res...

Страница 62: ...0 Non volatile memory capacity events 150 000 Support of SD cards 2 256 Gb Maximum recording time 1 camera 2 cameras 3 cameras 4 cameras 1700 h 850 h 560 h 420 h Inputs and outputs Ignition key input...

Страница 63: ...es CAN interface Yes RS 485 interface 1 RS 232 interface 1 USB interface Yes Voice communication connection Yes 1 wire interface Yes Ethernet Yes Built in accelerometer Yes Design Dimensions mm 225 18...

Страница 64: ...vers for data transmission 2 Remote control through GPRS Yes SIM card heating Yes Driver identification Yes Event photo registration Yes 1 Wire temperature sensors connection Yes Passenger sensors sup...

Страница 65: ...ermanently lighted Valid data from satellites are received 3G green Off Module power supply off Permanently lighted Within the GSM network coverage exchange with communication server is performed SD1...

Страница 66: ...R if the command is not forwarded to execution Request for disabling digital output GETIMG GETIMG param Possible parameter values param OK if the command is forwarded to execution param ER if the comm...

Страница 67: ...GETINFO INFO DID deviceID HW hardware_code_version BL bootloader_version FW firmware_version REC number_of_records_in_archive IMEI GSM_modem_unique_identifier Request for state of terminal RESET RESET...

Страница 68: ...pwdid vid identification of Terminal pwdid password identification SETPWDID ERRID ERRNulPWD ERRAlrSet PWD pwdid OK Setting parameter Password CONNECTSC CONNECTSC Request for connection of terminal wit...

Страница 69: ...GPSCOLD GPSCOLD ERR OK Cold start of GPS reciever UNBLOCK Unblocking the terminal Command Designation Command text in SMS Reply to a command in SMS SMS Commands OmnicommOKO video terminal 69...

Страница 70: ...info omnicomm world com www omnicomm world com...