6-1
S E C T I O N 6
System Programming
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Programming Methods
The system can be programmed using either of two methods:
•
Directly, using any supported keypad.
NOTES:
1. If there are no keypads connected to the system, keypad address 8 is automatically enabled. This
allows an OMNI-LCD to be temporarily connected for programming the system.
2. If XK-108 keypads are the only keypads used in the system, but you want to program the system
using an LCD keypad, you must power down the system, connect the LCD keypad, and then
power up the system. When you press the Stay button to exit installer programming, immediately
disconnect the LCD keypad, and the XK-108 keypads will re-initialize.
•
Remotely, using the PC DOWNLOADING software (Compass Downloader).
System Default
The system is shipped from the factory with specific default values suitable for a typical installation. If
the default values are suitable for your installation, then programming can be simplified. The default
values are listed with each programming question.
To reset the system to the default values, do one of the following:
A. Press the [1] and [3] keys at the same time while in the Installer Mode 1 programming mode.
B. Use Installer Mode 5 (press [CODE] + [
✱
] + installer code + [5] + [5]).
NOTE: After the entry of the first 5:
LCD keypads display –
System Default
<5> Yes <
✱
> No
Fixed-Word keypads display –
d5
C. Remove power (AC and DC), short JP1 and JP2, then re-apply power (with JP1 and JP2 still
shorted). Wait at least 8 seconds, and then remove the short with power still applied.
When the system is defaulted, the system will revert to factory-programmed values and go through the
reset and warm-up time sequence.
A programming option can be selected through the Compass Downloader Software known as
Default Lockout. If selected, a system default reset will change all of the programmable
options with the exception of the CSID (a code used by the software to identify the panel during
remote connections) and the installer code. This prevents hostile account takeovers.