Section 5. System Operation
5-7
RESET
Reset is accomplished through the entry of any valid user code. This can be used to reset the smoke
detectors attached to the system, silence any bells or sounders, or clear the keypad display.
BYPASS BY ZONE
Bypassing is enabled to temporarily exclude zones or points that are faulty or otherwise not ready for
operation, from activating the security system.
TO BYPASS by ZONE: Press the [BYPASS] key followed by any valid 4-digit user code, followed by
the zone number (01–24) representing the respective zone to be bypassed.
EXAMPLE: To bypass zone 6 (assume user code of 1234), press [BYPASS] + [1] + [2] + [3] + [4] + [0] +
[6]
QUICK BYPASS BY ZONE
Quick Bypassing is a programmable option (Question 14, Location 4) and allows the user to bypass
zones and points without using a user code.
TO Quick BYPASS by ZONE: Press the [BYPASS] key followed by the zone number (01–24),
representing the respective zone to be bypassed.
EXAMPLE: To bypass zone 6, press [BYPASS] + [0] + [6]
In addition, note the following rules for bypass:
•
FIRE zones cannot be bypassed.
•
24-hour zones can be bypassed; however, they CANNOT be unbypassed if they are violated.
•
Zones can be bypassed only while the system is disarmed, at which time the bypassed zone is
displayed.
Bypass signals will be transmitted to the central station (CS) UPON ARMING if a bypass code has
been programmed in Submode 2, Question 44, Location 1.
!
ZONES THAT ARE BYPASSED ARE NOT PROTECTED WHEN THE SYSTEM IS ARMED.
BYPASS LIMIT 3
The system can be programmed to allow a maximum of 3 zones to be manually bypassed in a partition.
You can also program the system to display bypasses while armed. See Submode 1, Question 16,
Location 1.
AUTO UNBYPASS
All burglary zones that are bypassed are automatically unbypassed upon system disarm. 24-hour zones
that have been bypassed will be unbypassed only if they are not violated.