Section 5. System Operation
5-5
1. Within 30 seconds of applying power to the unit, press the [CODE] and [STAY] keys at the same
time and hold them for several seconds.
2. When the display shows a single digit pulsing, enter the address 1–8 for fixed-word and for LCD
keypads.
3. To terminate the mode, press [
✱
].
Set the XK-108L keypad address by using its DIP switches. Refer to the instructions provided with the
keypad for additional information on setting the keypad address.
Arming the System
The system can be armed only if all burglary zones are in ready state (not faulted):
OMNI-LCD
OMNI-KP
XK-108L/XK-108
Indicator LED Lit
Ready
Ready
Ready
Display
SYSTEM READY
N/A
N/A
TO ARM: Enter any programmed four-digit user code.
NOTE: The factory default for user #1 is 1234.
The ARMED LED will light and the user may pass through interior zones (if necessary) and exit
through an exit/entry zone for the time period programmed as the exit delay.
LCD display keypads provide the following indications:
OMNI-LCD
OMNI-KP
XK-108L/XK-108
Indicator LED Lit
Armed
Armed
Armed
Display
ON: AWAY; EXIT NOW
AWAY
N/A
The system can be armed without the backup battery being connected; however, the AC/LB or BAT
light will flash depending on the keypad used.
Arm While Faulted: If programmed (Submode 1, Question 14, Location 2), the user can arm the
system while a delay or interior zone is still faulted.
AUTO STAY ARMING
TO ARM: Enter any programmed four-digit user code.
If the user does not access an exit/entry zone during the exit time and auto stay zones are programmed,
the panel arms Auto Stay and bypasses any zones programmed to do so.
OMNI-LCD
OMNI-KP
XK-108L/XK-108
Indicator LED Lit
Armed
Armed
Armed, Stay
Display
ON:AUTO STAY
STAY
N/A
NOTE: The system will not Auto Stay arm if an Instant zone is faulted when the user code is entered.