Section 5. System Operation
5-15
beeps every 15 seconds for 2 minutes prior to arming) warns the occupants that the system will auto-
arm in two minutes. If a user code is entered within this warning period and the system is disarmed,
the auto-arm time for that day will be canceled. The system will generate an audible acknowledgment
(1-second keypad sounder) and the lights on the LED display will scroll to show that the auto-arm time
was suspended. LCD-based keypads will display “AUTO-ARM CANCELED.”
The system will exit this mode either automatically (no keys pressed) after the last entry (MINUTE), or
when the star [
✱
] key is pressed.
NOTE: Auto-arming will arm the system and bypass any zones that are not ready. Therefore, it is
recommended that bypasses should be reported to the CS if auto-arming is programmed. Auto-arming
is not suitable for UL applications.
LOSS-OF-TIME WARNING:
If auto-arming has been enabled and no time is defined, a
warning will appear on the keypads. This can occur if time (#3 command) has not been
entered or if the system has totally lost power (AC & DC) and the time is probably incorrect.
The loss-of-time warning consists of the LEDs on the keypads scrolling in sequence or a text
message on LCD keypads. This will occur every 30 seconds until the time is set.
DISPLAY PANEL REVISION: # 55 (LCD Keypads Only)
Pressing [#] [5] [5] displays panel revision level on the LCD keypads.
The system exits this mode when the star [
✱
] key is pressed.
KEYFOB LOW BATTERY TEST: # 56
The keyfob low battery test can be activated by pressing: [
#] + [5] + [6]
LCD keypads display:
Fixed-word keypads display
Keyfob Bat. Test
#56
✱
=Exit
FO
AC
TEST
When a keyfob button is pressed, the system will provide a display indicating if the keyfob has a low-
battery condition.
NOTE:
The #56 command is available regardless of the programming entered for keyfob low battery
display (Submode 1, Question 16, Location 2).
The system exits this mode when the star [
✱
] key is pressed.
DOOR STRIKE: # 57
The door strike trigger can be activated by pressing:
[
#] + [5] + [7] + USER CODE
– OR–
[#] + [5] + [7] if no code for strike is enabled (Submode 1, Question 13, L1)
At least one of the triggers must be defined as a door strike trigger in order to use this feature.
Note that the door strike can also be activated by users 20 through 30 if the door users 20–30 option is
set (Submode 1, Question 13, L1).
UL
DOOR STRIKE is not a permitted programming option for any UL installation.