Page 14
* An optional doorlock interface must be installed. When Auxiliary
Output #2 is operated, all of the doors will unlock, even if the vehicle is
configured with Driver’s Door Priority.
Auxiliary Output Notes
:
- Auxiliary Output #2 may be activated anytime, provided the vehicle’s
ignition is off. While the ignition is on, the Auxiliary Output #2 can be
operated as long as a vehicle door is open; this prevents the output from
being accidentally activated while driving.
- If feature #7 is programmed to have the Auxiliary Output #2 disarm the
system, the doors will unlock when it is activated; and there is an audible
and visual confirmation: 3 siren chirps and one light flash if the system
also disarms, and one chirp and light flash otherwise.
- Auxiliary Output #3 may be activated at any time, regardless of the igni-
tion being on or off, and regardless of the security system’s status.
- Auxiliary #3 has no audible and/or visual confirmation.
Sensors:
The Crime Guard 850i
3
security system is equipped with a Glass
Breakage and Dual-Zone Infrasonic Impact Sensor to increase the
effectiveness of the system. The impact sensor is just one in a comprehensive
line of available sensors. Other available options are: piezo shock sensors,
and microwave/radar sensors which can detect objects in motion both inside
and outside the vehicle.
- The Crime Guard 850i
3
control module features dual auxiliary sensor
ports, which easily allows the addition of a further optional sensor.
- If desired, the sensor zone only can be bypassed when the system is armed
with the transmitter, but leaving the other protection zones in place. This
feature is convenient when environmental factors, such as hail or thunder
storms, may lead to the system being activated erroneously.
Prewarning Detection Circuit:
When the sensor’s prewarn zone is
violated the security system will respond by chirping the siren three times
and relocking all of the doors.* If the prewarn circuit is triggered five times
while the system is armed, the circuit will automatically shutdown until the
security system is disarmed and armed again.
- Prewarning operates from the Infrasonic Impact Sensor only.
GLASS BREAKAGE & 2-ZONE IMPACT SENSOR
* An optional doorlock interface must be installed