Outdoor Living Today www.outdoorlivingtoday.com [email protected]
Page 29
D10.
To further secure roof panels from the inside, drill pilot holes on an angle in each panel’s
Mid Rafter (3 per Rafter).
Using 3 - 2 1/2” Screws,
secure rafters to plywood.
Note:
from outside
if possible, have a helper push roof panel down so plywood sits flush against rafter while securing.
Locate
Top Siding Piece for Angled Wall Extender (L/R)
. Position top siding on wall extender
and align as shown above. Attach with
3 - 1 1/2” Finishing Nails
to top wall framing. There are
left/right top siding pieces. Use rough surface side out.
Mid Rafter
Plywood
3 - 2 1/2” screws Toe
Nailed in each Mid Rafter.
D11.
Position first
Roof Ridge Board
(1/2” x 4 1/2” x 51 5/8”)
at the rear of roof to cap off shingles
and facia. Ridge Boards should meet on seam of roof panels. When aligned correctly, attach with
4 - 1 1/2” Finishing Nails
per piece.